PlaBase

Public Beta

PlaBase

HTNFR42G30NH BK337 | Zytel

Manufacturer

Celanese Corporation

Resin Name

PPA

Product Name

Zytel

ISO Material Code

PA-GF30 FR(40)


Basic Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Density

Density/ISO 1183

Density

ISO 1183

g/cm^3

1.47

-

Water absorption

Water absorption/ISO 62

Balanced water absorption (2mm)

ISO 62

%

1

-



Thermal Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Deflection Temperature under Load

Deflection Temperature under Load/ISO 75-1/-2

Deflection temperature under load (1.80MPa)

ISO 75-1/-2

276

-

Linear expansion coefficient (MD)

Linear expansion coefficient (MD)/ISO 11359-1/-2

Linear expansion coefficient (parallel)

ISO 11359-1/-2

x10^-5/℃

2.1

-

Linear expansion coefficient (TD)

Linear expansion coefficient (TD)/ISO 11359-1/-2

Linear expansion coefficient (right angle)

ISO 11359-1/-2

x10^-5/℃

5.5

-



Mechanical Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Tensile breaking stress

Tensile breaking stress/ISO 527-1/-2

Breaking stress (when completely dry)

ISO 527-1/-2

MPa

130

-

/

110

-

Tensile strain at break

Tensile strain at break/ISO 527-1/-2

Breaking strain (when completely dry)

ISO 527-1/-2

%

1.9

-

Breaking strain (when humidity controlled)

ISO 527-1/-2

%

1.4

-

Tensile Modulus

Tensile Modulus/ISO 527-1/-2

Tensile modulus (when completely dry)

ISO 527-1/-2

MPa

11700

-

Bending strength

Bending strength/ISO 179

Bending strength (when completely dry)

ISO 179

MPa

210

-

Flexural modulus

Flexural modulus/ISO 178

Flexural modulus (when completely dry)

ISO 178

MPa

11000

-

Flexural modulus (when conditioned)

ISO 178

MPa

11000

-

Charpy impact strength

Charpy impact strength/ISO 179/1eA

Notched Charpy impact strength (23°C) (when completely dry)

ISO 179/1eA

kJ/m^2

7

-

Notched Charpy impact strength (-30℃) (absolutely dry)

ISO 179/1eA

kJ/m^2

6

-

Charpy impact strength (23℃) (when not exposed to heat)

ISO 179/1eU

kJ/m^2

35

-

Charpy impact strength (-30℃) (when completely dry)

ISO 179/1eU

kJ/m^2

35

-



Electrical Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Volume resistivity

Volume resistivity/IEC 62631-3-1

Volume resistivity

IEC 62631-3-1

Ω・cm

NaN

-

Dielectric Strength

Dielectric Strength/IEC60243-1

Withstand voltage (when completely dry)

IEC60243-1

kV/mm

33

-

Tracking resistance

Tracking resistance/IEC60112

Tracking resistance (when completely dry)

IEC60112

600

-



Standard Building Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Drying conditions

Drying conditions/-

Drying temperature

-

100

-



Filler Content Rate

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Filler Content

Filler Content/ISO 16620-2

Biocarbon Content

ISO 16620-2

%

20

≥Minimum

Filler Content

%

30

GF



Key Features

Flame retardant, halogen-free, high flow, reflow resistance