PlaBase

Public Beta

PlaBase

HTN55G55TLW BK117 | Zytel

Manufacturer

Celanese Corporation

Resin Name

PA

Product Name

Zytel

ISO Material Code

PA-I-GF55


Basic Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Density

Density/ISO 1183

Density

ISO 1183

g/cm^3

1.66

-

Water absorption

Water absorption/ISO 62

Water absorption (immersion, 24h)

ISO 62

%

0.6

-



Thermal Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Deflection Temperature under Load

Deflection Temperature under Load/ISO 75-1/-2

Deflection temperature under load (1.80MPa)

ISO 75-1/-2

236

-



Mechanical Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Tensile breaking stress

Tensile breaking stress/ISO 527-1/-2

Breaking stress (when completely dry)

ISO 527-1/-2

MPa

243

-

Tensile strain at break

Tensile strain at break/ISO 527-1/-2

Breaking strain (when completely dry)

ISO 527-1/-2

%

1.8

-

Tensile Modulus

Tensile Modulus/ISO 527-1/-2

Tensile modulus (when completely dry)

ISO 527-1/-2

MPa

18700

-

Bending strength

Bending strength/ISO 178

Bending strength (when completely dry)

ISO 178

MPa

360

-

Flexural modulus

Flexural modulus/ISO 178

Flexural modulus (when completely dry)

ISO 178

MPa

17000

-

Charpy impact strength

Charpy impact strength/ISO 179/1eA

Notched Charpy impact strength (23°C) (when completely dry)

ISO 179/1eA

kJ/m^2

18

-

Notched Charpy impact strength (-40℃) (absolutely dry)

ISO 179/1eA

kJ/m^2

20

-

Charpy impact strength (23℃) (when completely dry)

ISO 179/1eU

kJ/m^2

75

-



Electrical Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Tracking resistance

Tracking resistance/IEC 60112

Tracking resistance (when completely dry)

IEC 60112

600

-



Standard Building Properties

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Drying conditions

Drying conditions/

Drying temperature

100

-



Filler Content Rate

Blurred items can be viewed by registering or logging in.

Blurred items can be viewed by registering or logging in.

PropertyDetailsInspection MethodsUnitValueNote

Filler Content

Filler Content/

Filler Content

%

55

GF




PlaBase

Copyright© 2026 PlaBase. All Rights Reserved.